Alaris/Cardinal Imed Gemini PC-1 Infusion Pump

Alaris/Cardinal Imed Gemini PC-1 Infusion Pump

Save up to 80% on pre-owned Alaris/Cardinal Imed Gemini PC-1 infusion pumps.
   Request A QUOTE!


Product Specifications

Operating Principle:
Linear peristalsis

Dimensions:
10.8" x 8.2" x 6.5" (27.5 cm x 20.6 cm x 16.5 cm)

Weight:
11.3 lbs (5.1 kg)

Power Requirements:
90 - 130 (120 nominal) VA, 0.5A, 50/60 Hz, 3 wire, single phase

Battery Operation:
With a new battery, approximately 5 hours At 125 ml/hr before a "HELP BATTERY"

Electrical Leakage:
Less than 100 microamps

Delivery Rate Range

Micro:
0.1-999 ml/hr (Note: Recommended maximum rate in the Controller Mode is 500 ml/hr

Macro:
0.1-99.9 ml/hr (in 0.1 ml/hr increments)

Volume to be Infused

Micro:
0.1-999.9 m/l (in 0.1 ml increments)

Macro:
1-9999 ml (in 1 ml increments)

KVO (Keep Vein Open) Rate:
1 ml/hr if set rate is 1 ml/hr or above, or actual rate if set at 0.9 ml/hr or below

Occlusion Pressure

Pump mode:
10 ±2 psi for rates above 30 ml/hr. For rates of 30 ml/hr and below, the occlusion pressure will be less than 10 psi, and is rate dependent (unless locked into 10 psi for all rates)

Advisories:
Secondary, Primary, Infusion Complete - KVO, Empty Container-KVO, Low Battery, Maintenance, Pause, On Batt, 10 psi. Flow, Total Vol Infused, Sec Vol Infused Macro, Micro, Versataper: Setup, Step: xx, Steps: xx, Total Vol: xx, Duration: xx, Versataper, and Time Left:xx

Prompts:
Select P/C mode, set rate, set VTBI, and Press Start

Alarms:
Check ECD, Check IV Set, Close Door, Air-in-Line, Occluded Patient Side, Occluded Fluid Side, Occluded, Partial Occlusion Fluid Side, Flo-Stop Open/Close Door, KVO Comm Cable, KVO Comm Tout, and KVO

Malfunctions:
Help internal error, help battery, and (Watchdog Malfunction)

Secondary (Piggyback):
Dual rate programming



Get the Original Operation Manual Here

Get the Remastered Operation Manual Here

We proudly rent, sell, and maintain this equipment. Imed and Gemini are trademarks of Carefusion



For service, parts, PM or rental see our Services section


      Slothworks

This site gathers traffic statistics to improve service to different regions. Continued browsing constitutes acceptance.

Copyright © 2010 All Rights Reserved. Ardus Medical, Inc. | 1-855-59-Ardus | info@ardusmedical.com | Site Map
 
Medical Products by Ardus